Troubleshooting a Reefer Unit That Won't Cool Properly

Learn how to troubleshoot a reefer unit that won’t cool properly. This Dallas-focused guide addresses refrigerant issues, compressor problems, electrical faults, and other common issues.
Diesel engine

When a reefer unit fails to cool properly, it’s more than just an inconvenience — it threatens load integrity, client trust, and DOT compliance. For fleets and operators in the DFW reefer repair space, being able to troubleshoot a reefer unit that won’t cool properly can be the difference between a minor repair and a significant financial loss.

In this comprehensive guide, we’ll break down the most common causes of reefer failure, how to diagnose them, and what steps you can take, whether you're a fleet manager, technician, or owner-operator based in Dallas.

Understanding How a Reefer Unit Works

Before diving into troubleshooting, let’s briefly review how a refrigeration system operates. The system operates through a closed-loop cycle, comprising a compressor, condenser, expansion valve, and evaporator. The refrigerant circulates through these components to absorb heat from the cargo space and expel it outside. This process depends on proper airflow, sensor input, and electrical control. When one part fails, the entire cooling cycle can break down.

Common Causes of Reefer Units Not Cooling

1. Low or Contaminated Refrigerant

Refrigerant is essential to the cooling cycle. A low refrigerant charge due to a leak or contaminated refrigerant prevents the reefer from effectively absorbing heat. Troubleshooting tips:

  • Visually inspect refrigerant lines for oil residue, a standard indicator of a leak.
  • Use a refrigerant manifold gauge to verify system pressure.
  • Check for signs of moisture contamination, which can freeze and block refrigerant flow.

Fix: Recharge the system with the correct refrigerant and repair any leaks that may be present. Replace the receiver-drier if moisture is detected.

2. Compressor Issues

The compressor pressurizes the refrigerant, keeping it circulating—a malfunctioning compressor results in ineffective or no cooling at all. Key indicators:

  • No clutch engagement when the unit calls for cooling.
  • Unusual noises like rattling or grinding.
  • Discrepancies in high-side/low-side pressures.

Fix: Test the clutch coil with a multimeter. If it fails, replace the compressor and flush the system.

3. Blocked or Dirty Condenser and Evaporator Coils

Dirty or blocked coils reduce heat exchange efficiency, forcing the unit to work harder and still fail to cool properly. What to look for:

  • Dirt, road debris, or bugs on the condenser fins.
  • Ice buildup on the evaporator coils.
  • Poor airflow through vents.

Fix: Clean coils with approved cleaners and soft bristle brushes. Check the evaporator drain lines and verify that the blower fan is functioning correctly.

4. Thermostat or Sensor Malfunction

Temperature sensors and thermostats are critical for monitoring internal conditions. A faulty sensor can send incorrect readings to the ECM, triggering false alarms or preventing the cooling system from functioning correctly. Symptoms:

  • Wide variations in box temperature.
  • Control panel showing incorrect temperature.
  • Frequent cycling or failure to engage the compressor.

Fix: Test sensor resistance values and replace damaged sensors. Ensure sensor wiring is intact and properly routed away from hot components.

Electrical Failures That Impact Cooling

5. Blown Fuses and Relays

Reefer units rely on a dedicated electrical system with fuses, relays, and control boards. One blown fuse or a stuck relay can halt the entire unit. Quick checks:

  • Inspect the fuse panel for blown or missing fuses.
  • Use a test light or multimeter to check the voltage at the relays.
  • Wiggle test harnesses for intermittent power loss.

Fix: Replace failed components. Clean corroded terminals and seal exposed connections with dielectric grease.

6. Faulty Control Board or Software Errors

Modern reefers are computer-controlled. ECMs and PCMs manage compressor operation, fan speed, and temperature regulation. Faults here can mimic mechanical problems. How to diagnose:

  • Use an OEM-specific diagnostic scanner to check for fault codes.
  • Reset or update firmware if prompted.
  • Watch for software “hangs” that prevent cycling.

Fix: Reload the software and verify module operation. Replace the ECM if it fails bench tests.

Mechanical Failures and Wear

7. Damaged Belts, Pulleys, or Tensioners

If your reefer uses a belt-driven compressor, a damaged or loose belt may prevent the system from cooling. Check for:

  • Cracks or fraying on the belt.
  • Slipping belt or squealing noise on startup.
  • Misaligned pulleys or weak tensioner springs.

Fix: Replace worn belts and check pulley alignment. Tension belts to manufacturer specs.

8. Expansion Valve Blockage

The expansion valve regulates the amount of refrigerant that flows into the evaporator. If it's clogged or stuck, you may see frost or a complete loss of cooling. Tell-tale signs:

  • Frost after the valve, but a warm evaporator.
  • Sudden pressure drop on the low side.
  • Temperature swings without explanation.

Fix: Replace the valve and install an inline filter dryer to prevent repeat contamination.

Operational and Environmental Factors

Even a fully functional reefer unit can struggle due to environmental conditions or incorrect use.

9. Cargo Loading Practices

Improperly loaded cargo blocks airflow and limits heat exchange. Boxes too close to vents or improper stacking patterns can cause “hot spots.” Best practices:

  • Keep cargo at least 3–4 inches from airflow vents.
  • Avoid overloading, as this can cause the unit to overwork.
  • Use bulkheads to improve circulation.

10. External Temperature Extremes

In Dallas summers, ambient temperatures can exceed 100°F. If the reefer is undersized or already struggling, it may not maintain desired box temps.

Tips:

  • Pre-cool the box before loading.
  • Avoid extended door-open periods.
  • Park in shaded areas whenever possible.

When to Call a DFW Reefer Repair Specialist

Some issues go beyond roadside troubleshooting. In such cases, consulting a local DFW reefer repair specialist is crucial. Here’s when to bring in a pro:

  • Persistent fault codes despite resetting
  • Electrical faults involving the control board
  • Compressor clutch not engaging even with proper voltage
  • Suspected refrigerant contamination or internal blockage

Look for a shop experienced in Thermo King, Carrier Transicold, and other leading reefer brands. Ensure they have refrigerant recovery machines, diagnostic software, and pressure testing tools.

Preventive Measures to Avoid Reefer Failures

Regular maintenance reduces the risk of costly downtime. Here's what your PM checklist should include:

  • Verify refrigerant charge and check for leaks
  • Clean coils quarterly (more often in dusty environments)
  • Test thermostat and sensor calibration
  • Inspect all belts and electrical connections
  • Run a full diagnostic scan during scheduled service

Preventive care is especially crucial during high-demand seasons in Texas, where breakdowns can result in heat-damaged cargo, potentially leading to significant losses.

Conclusion

A reefer unit that won’t cool properly can be caused by a variety of issues, ranging from a simple blown fuse to a failed compressor. By understanding how your unit works, following a methodical diagnostic process, and maintaining it regularly, you can keep your fleet cool and your cargo protected.

If you’re in Dallas and your reefer unit continues to underperform, don’t wait until you’re facing a rejected load or a fine. Contact a trusted DFW reefer repair provider to get expert diagnostics and dependable solutions.